ELECTRON BEAM ACCELERATOR
- It is a new and simple method to produce new materials by chemical reactions by electrons accelerated with Electron Beam Accelerator
|
 |
+ Principal : The accelerated electrons given to the materials produce excitation or ionization of molecules resulting in chemical reactions.
|

-
Various Models
– Variety of Models with the energy from 0.4 ~ 10.0 MeV
-
High Efficiencies and economy
– High efficiencies and economies due to simplified design
-
Highly Reliable Control Systems
– Precise control system ensure high reliability and stabilized operation
-
Safe and Simplified control
-Easily operated by computer control, but interlock safety system promises the safety of facility and operator
-
Simple maintenance
– Simple designs enable easy maintenance
-
Quick Recovery
– Prompt after-service available
Type : ELV-4
|
Equipment
|
Mass (kg)
|
Dimension (mm)
|
Accelerator
|
3850
|
4140 × 1345
|
Inverter/Reactor
|
700
|
1650 × 1200 × 740
|
Control cabinet
|
150
|
1800 × 600 × 750
|
Gas system
|
1500
|
1680 × 2200 × 850
|
|
0.8~1.5
|
Energy (MeV)
|
100
|
Electron Beam opower(kW)
|
50~100
|
Beam current not more(mA)
|
10
|
Non-uniformity of current linNon-uniformity of current ear density along 80% of the extraction window not more (%)
|
980
|
Extraction window dimension not more (mm)
|
220/380
|
Input voltage (V)
|
3
|
Number of phase
|
50/60
|
Frequency (Hz)
|
148
|
Power consumption (kW)
|
Type : ELV-8
|
Equipment
|
Mass (kg)
|
Dimension (mm)
|
Accelerator
|
7000
|
6287 × 2200
|
Inverter
|
700
|
1650 × 1200 × 740
|
Reactor
|
600
|
1650 × 1200 × 740
|
Control cabinet
|
150
|
1800 × 600 × 750
|
Gas system
|
1500
|
1680 × 2200 × 850
|
|
1.0~2.5
|
Energy (MeV)
|
100
|
Electron Beam opower(kW)
|
50
|
Beam current not more(mA)
|
10
|
Non-uniformity of current linear density along 80% of the extraction window not more (%)
|
1500
|
Extraction window dimension not more (mm)
|
220/380
|
Input voltage (V)
|
3
|
Number of phase
|
50/60
|
Frequency (Hz)
|
148
|
Power consumption (kW)
|
Type : ELV-12
|
Equipment
|
Mass (kg)
|
Dimension (mm)
|
Accelerator
|
10000
|
6515 × 6420
|
Inverter/Reactor
|
1500
|
1500 × 800 × 1600
|
Control cabinet
|
150
|
1800 × 600 × 750
|
Gas system
|
1500
|
1680 × 2200 × 850
|
|
0.8~1.0
|
Energy (MeV)
|
400
|
Electron Beam opower(kW)
|
400
|
Beam current not more(mA)
|
10
|
Non-uniformity of current linear density along 80% of the extraction window not more (%)
|
1600
|
Extraction window dimension not more (mm)
|
220/380
|
Input voltage (V)
|
3
|
Number of phase
|
50/60
|
Frequency (Hz)
|
500
|
Power consumption (kW)
|
Type : ELV-3M
|
Equipment
|
Mass (kg)
|
Dimension (mm)
|
Accelerator
|
3850
|
1550 ×1365
|
Inverter
|
700
|
1650 × 1200 × 740
|
Control cabinet
|
150
|
1800 × 600 × 750
|
Gas system
|
1500
|
1680 × 2200 × 850
|
|
0.5~0.7
|
Energy (MeV)
|
20
|
Electron Beam power(kW)
|
33
|
Beam current not more(mA)
|
±10
|
Non-uniformity of current linear density along 80% of the extraction window not more (%)
|
640
|
Extraction window dimension not more (mm)
|
220/380
|
Input voltage (V)
|
3
|
Number of phase
|
60
|
Frequency (Hz)
|
30
|
Power consumption (kW)
|
- Irradiation room is shielded by Concrete or Lead
- Designed based on Monte-Carlo method(MCNP) for radiation leakage calculation
- Can be changed the structure according to customer’s request
- Total solution with cable, tube and sheet handling system
|
 |